Time ago we saw a guide for the use of total station in the cadastre; in this, appears the capture of information.
Now we’ll see how to download data to the computer, using one of the guides that made by one of my technicians. Indeed, it’s a great job. I’m using for this:
ProLink Software. ProLink is used for: downloading data from any Sokkia device; editing of field data; reduction of raw data, RTK GPS and Total Station alike; import and export of various file formats as well as creation of your own conversions; management of coordinate system files (GPS). Sokkia Prolink Download, free sokkia prolink download software downloads, Page 3. Sokkia Prolink Download, free sokkia prolink download software downloads, Page 3.
Sokkia Prolink Download Software Download Wonder v.1.60 Download Wonder® works seamlessly with your browser to download files from the Internet, then manage and organize your downloads.
USB Data Transfer Cable
Prolink 1.15
1. The earlier “extra gft”
For some strange reason, the transfer cable was damaged a few times with my first total station. Although the boys are careful, we couldn’t find any reasons; rather than the possibility that, not having belt with which to tie the cow’s tail, it must have been used for that purpose… with similar results.
Free Download Prolink Version 1.15
I’ve seen a transfer cable (as shown in picture) that has the bulb where the chip is inserted; when it’s placed at the end, it is more efficient than if it’s placed at its center. I think that in that fucking desperation, they inserted and removed the cable in a quickly and wrong way, and that was the reason the chip was burnt.
2.Prepare the station for the transfer
Having connected the transfer cable (USB to serial converter), then indicate that what we hope is to transfer data, and which jobs:
MEM> JOB> then we press Enter.
In the next panel select Comms Output, and then press Enter.
Then select the work to be transferred. Note that, when selected, instead of appearing the amount of captured points, text is changed to Out, which means it is ready to be transferred.
What follows is just to select the OK option, with SDR33 format, and then appears a message which indicates that data is being transferred and the amount of points in the process. Mind you, this is done until it is set up the connection from the Prolink, which is explained below.
3. Configuring Prolink
Sokkia Prolink 1.15 Software Download
The project. To do this, we do File> New Project, and assign the file name that will be store in SPP format. This may be open in the future, in case we close the program and need to go back to the same project. There is a new project for each JOB; if not … you will tell me.
The connection. Now we press the reception icon, or choose these command’s sequence File > Send-receive. Then we will see the download panel, where we will set some parameters:
In Settings, we will establish that the port to use will be COM4, the Baud rate chosen 1200, none parity, 8 data bits and stop bits 1. This is done only once, and sometimes you have to try more than one port. Owners manual for new holland 855 baler.
With the Connect button, the connection is tested and if found, the station will be visible with the name:
Powerset File SDR.
Sokkia Sdr33 Download Software
The button changes from the Connect to the Disconnect option.
The transfer. Once selected, with the transfer button (the Middle arrow), the download is active.
Beware, at this time the sending must be activated from the total station, as it’s mentioned at the end of paragraph 2.
Finally, you should see the complete transfer message. What happiness, the cow did not damage the cable.
Import / Export. So far, what we have done is to transfer the data set. To import the set to the panel, do File> Import, select the downloaded package and then we can see the raw data.
What come are export points to DXF. Thus, it becomes File> Export, and chooses the point with annotations.
Prolink Software Corporation is committed to respecting and protecting your privacy. To that end, we have prepared this privacy statement to disclose and describe our information gathering and dissemination practices for this website.
Notice and Disclosure
In general, you may visit this website without identifying yourself or revealing any personal information. Prolink collects domain information from your visit to customize and improve your experience on our website. Some portions of this website may require you to give us personally identifiable information, which is information that enables us to identify you, such as your name, email or other address. If you opt to provide this information, we may also use it for purposes such as verifying your identity, sending you information, or contacting you.
Cookies
Sokkia Prolink Free Download
Portions of this website may use cookies to keep track of your visit, or to deliver content specific to your interests. A cookie is a small amount of data transferred to your browser and read by the Web server that placed it there. It works as a sort of identification card, recording your preferences and previously entered information. You can set your browser to notify you when you receive a cookie, giving you the chance to accept or reject it.
Sokkia Link software, free download
Contact Us
Sokkia Prolink 1.15 software, free download
If you have any questions or comments about our privacy statement or practices, please contact us via email at [email protected] with the words 'PRIVACY POLICY' in the subject line. Prolink Software reserves the right to modify or update this privacy statement at any time without notice. Last updated February 13, 2018.